Notice, Confirm the refrigerant – LG LA120CPI User Manual

Page 14

Advertising
background image

14 Room Air Conditioner

1. Check the quality label on the indoor and outdoor unit.

2. Make certain that the refrigerant is R-410A.

THIS PRODUCT CONTAINS R-410A REFRIGERANT

1) Different compressor oil

- R-410A(Polyol ester) / R-22(Mineral).
- Do not mix the existing mineral oil.
- Do not apply used pipe, tools and gauges covered with the existing mineral oil.

2) Absorption of moisture

-Compressor’s oil has the high absorption rate of moisture.

3) Composition

- R-410A(R32:R125=50:50wt%).
NOTE: Never mix with other refrigerants

4) High pressure.

- 1.6 times higher than R-22.
- High Pressure refrigerant may cause personal injury.

Do not handle the pipe by yourself (customer) High-pressure refrigerant may cause personal injury.
- manifold gauge ,charging and any piping tools must be dedicated to R-410A systems.

NOTICE

Confirm The Refrigerant

Boiling Pt.(°C)

Vapor pressure(25°C)(kg f/cnf)

Vapor density(25°C)(kg/m

2

)

R-410A

-51.4

15.9

64

R-22

-40.8

9.6

44.4

Example : Split type 12,000 Btu/h

120

Capacity

[%]

100

100%

100%

70%

50%

30%

0%

70%

50%

30%

0%

100

93

89

84

76

80

60

40

20

0

R-410A
R-22