38 Room Air Conditioner

. Auto Operation (Electronic control mode)

• The operation procedure is shown below. (Cooling & Heating Model)

If initial mode is decided, that mode is continued without the room temperature changing.

Auto Operation for Cooling

Press Start/Stop Button

Select Auto Operation Mode

Check the Room temperature

Operation mode

Indoor fan speed

are decided automatically by the unit electronic control.

Setting temperature

Intake-air

temperature

Operation Mode

Over

below

70°F

76°F

Soft Dry

below 70°F

Heating

Over 76°F

Cooling

~

INTAKE AIR TEMP.

SETTING TEMP. +1°F
(Compressor OFF)

SETTING TEMP. -1°F
(Compressor ON)

COMPRESSOR

ON

OFF

ON

OFF

INDOOR FAN SPEED

The electronic control operation

Intake-air Temperature

Setting Temperature

Over 78°F

77°F

Over 76°F~below 78°F

Intake air -1°C

Over 72°F~below 76°F

Intake air -0.5°C

Over 68°F~below 72°F

Intake air temperature

below 64°F

64°F

Over 64°F~below 86°F

Electronic control

below 64°F

64°F

over 86°F

86°F

Operation Condition

When Auto Operation
initial start

Controlled by
the electronic
control

In this mode,
when pressing
the vertical air
direction control
button, vertical
louver swings up
and down
automatically.

Fan Speed

Air Direction Control

When pressing room
temperature setting
button during Auto
Operation

Operation

Advertising