Checking the Drainage

To check the drainage.

1. Pour a glass of water on the evaporator.

2. Ensure the water flows through the drain hose of the

indoor unit without any leakage and goes out the
drain exit.

Drain piping

1. The drain hose should point downward for easy drain

flow.

2. Do not make drain piping like the following.

Downward slope

Do not raise

Accumulated
drain water

Tip of drain hose
dipped in water

Air

Waving

Water
leakage