Cycle parts, Notice – LG LA120CPI User Manual

Page 62

Advertising
background image

62 Room Air Conditioner

Troubleshooting Guide

Cycle Parts

Trouble analysis

1. Check temperature difference between intake and discharge air and operating current.

Temp. Difference

Temp. difference : approx. 0˚F(0°C)
Current : less than 80% of

rated current

Temp. difference : approx. 14°F(8°C)
Current : less than 80% of

rated current

Temp. difference : less than 14°F(8°C)
Current : over the reated

current

Temp. difference : over 14°F(8°C)

Operating Current

• All amount of refrigerant leaked

out. Check refrigeration cycle.

• Refrigerant leakege

Clog of refrigeration cycle
Defective compressor

• Excessive amount of refrigerant

• Normal

Temperature difference between intake and discharge air depends on room air humidity. When the room air
humidity is relativery higher, temperature difference is smaller. When the room air humidity is relatively lower
temperature difference is larger.

2. Check temperature and pressure of refrigeration cycle.

1. The suction pressure is usually 4.5~6.0 kg/cm

2

G(Cooling) at normal condition.

2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with

putty.

NOTICE

NOTICE

Suction pressure

Temperature

(Compared with

(Compared with

Cause of Trouble

Description

the normal value)

the normal valve)

Defective compressor

Current is low.

Defective 4-way reverse valve

Excessive amount of

High pressure does not quickly

Normal

refrigerant

rise at the beginning of
operation.

Insufficient amount of

Current is low.

Lower Higher

refrigerant

(Leakage)

Clogging

Current is low.

High

Higher

Advertising
This manual is related to the following products: