Connecting the piping – LG LA120CPI User Manual

Page 20

Advertising
background image

20 Room Air Conditioner

Flaring work and connection of piping

Check

1. Compare the flared work with the figure by.

2. If a flared section is defective, cut it off and do flaring

work again.

Indoor

Preparing the indoor unit's piping and drain hose for installation through the wall.

CAUTION: If the drain hose is routed inside the room, insulate the hose with an

insulation material* so that dripping from "sweating"(condensation) will not dam-

age furniture or floors.
*Foamed polyethylene or equivalent is recommended.

1. Route the indoor tubing and the drain hose in the

direction of rear left or right

2. Tape the tubing, drain hose and the connecting cable.

Be sure that the drain hose is located at the lowest
side of the bundle. Locating at the upper side can
cause drain pan to overflow inside the unit.

Inclined

Inside is shiny without scratches

Smooth all round

Even length

all round

Surface

damaged

Cracked Uneven

thickness

= Improper flaring =

Connecting the Piping

Drain hose

Connecting
cable

Gas side piping

Liquid side piping

Drain hose

Loop