7. Cooling or Heating Mode with Sleep Mode Auto Control

• When selecting the Cooling(

) or the Heating( ) combined with the Sleep Mode Auto Control( ), the

operation diagram is as following.

Cooling Mode with the Sleep Mode

• The setting temperature will be automatically raised by 2°F 30 minutes later and by 4°F 1 hour later.

• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

Heating Mode with the Sleep Mode(only Heating Model)

• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

INTAKE AIR TEMP.

SETTING TEMP. +1°F
(Compressor ON)

SETTING TEMP. -1°F
(Compressor OFF)

30 minutes

30 minutes

More than

3 minutes

2°F

2°F

More than

3 minutes

COMPRESSOR

ON

OFF

ON

OFF

ON

INDOOR FAN SPEED

Low

Low

Low

Low

Low

SETTING TEMP. +6°F
(Compressor OFF)

SETTING TEMP.
(Compressor ON)

COMPRESSOR

ON

OFF

ON

OFF

ON

OFF

INDOOR FAN SPEED

Med

Low or OFF

Med

Low or OFF

Med

Low or OFF

INTAKE AIR TEMP.

More than

3 minutes

More than

3 minutes

More than

3 minutes

Operation