Recording setup screen – Panasonic AG-HPX500E User Manual

Page 123

Advertising
background image

123

Setup menu list

C

h

ap

te

r 7 M

en

u O
p

er

at

io

n

s

RECORDING SETUP screen

Item

Description of settings (Items in bold are factory settings.)

REC FORMAT

Selects the recording format for P2 card.

59.94Hz System: 1080i/60i, 1080i/30P, 1080i/24P, 1080i/24PA,

720P/60P, 720P/30P, 720P/24P,

720P/30PN, 720P/24PN, 480i/60i, 480i/30P, 480i/24P, 480i/24PA

50 Hz System:

1080i/50i, 1080i/25P, 720P/50P, 720P/25P, 720P/25PN, 576i/50i, 576i/25P

480i (576i)

REC MODE

Selects the 480i (576i) recording mode.
Enabled during SD mode recording.

DVCPRO50 / DVCPRO/DV

REC FUNCTION

Selects the special recording mode.

NORMAL, INTERVAL, ONE SHOT, LOOP

ONE SHOT TIME

Selects the one-shot recording time.

1F, 2F, 4F, 8F, 16F, 1s

INTERVAL TIME

Sets the interval time (INT) for interval recording (INTERVAL REC).

2F, 4F, 8F, 16F, 1s, 2s, 5s, 10s, 30s, 1m, 5m, 10m

START DELAY

Sets the START delay time for INTERVAL REC and ONE SHOT REC.

ON,

OFF

PREREC MODE

Sets PRE RECORDING to ON or OFF. (Fixed to 3 seconds for HD and 7 seconds for SD)

ON,

OFF

TC MODE

(only when set to

59.94 Hz)

/

Selects the time code correction mode when recording the time code output by the internal time code
generator.

DF: Uses the drop frame mode.

NDF: Uses the non-drop frame mode.

The non-drop frame mode is used when a frame rate of 24P, 24PA, or 24PN is selected in a recording
format regardless of TC MODE setting.

TC IN UB REGEN

Selects the user bits to be recorded when recording signals from a device connected to the TC IN
connector.

ON: Records the user bits of the signal input to the TC IN connector.

OFF: Records the user bits selected in the menu option UB MODE.

• Setting this option to ON prioritizes the input signal over the settings made in the menu option UB

MODE.

• No user bits are recorded when the input signal does not contain any user bits.
• Settings of the menu option UB MODE are used when no signal is input to the TC IN connector.

UB MODE

/

Set the content for user information.

USER: Records the information of user.

TIME: Records the time at recording.

DATE: Records the date at recording.

TCG: Records the values of the time code generator.

FRM. RATE: Records the frame rate information for frame conversion.

a

c

b

d

a: Checking information for user information
b: Frame sequence No.
• 0 to 4 are displayed in 24P/24P (ADV) mode.
• F is displayed in the modes other than above.
c: Frame rates
• Frame rate (60/30/24)
• I/P ID
• Conversion data
• Frame rate coefficient
d: Recording management data
• Frame update information
• REC START/STOP information
When connecting the HD SDI output to an external device (with HD SDI input) for backing up data, set
UB MODE to FRM.RATE to enable control of recording start/stop from the camera.
The external device has to be set up when automatic recording is desired. For details, refer to the
Operating Instructions supplied with the device.

MCR FORMAT

Selects playback or 1394 input format.

When operating at 59.94 Hz: 1080i/60i,

720P/60P, 720P/30PN, 720P/24PN, 480i/60i

When operating at 50 Hz:

1080i/50i, 720P/50P, 720P/25PN, 576i/50i

720P/30PN, 24PN and 25PN are available only for playback.

480i (576i)

MCR MODE

Selects the 480i (576i) playback mode, or 1394 input format.

DVCPRO50 / DVCPRO/DV

Advertising