Setting Time Data

C

h

ap

te

r 4 A

d

ju

st

m

en

ts a
n

d S
et

tin

g

s f

o

r R
ec

o

rd

in

g

GENLOCK and time code input/output connection and
setup

Camera operating conditions

Camera setup

GENLOCK input and camera output

phase (In phase: Out of phase: ×)

Recording

format

Video and reference

signal to be output

externally

GENLOCK

input

GL SELECT GL PHASE SDI OUT

VIDEO

OUT

TC OUT

Connection

diagram

1080i

SDI OUT (1080i)

1080i

SDI

Disabled

×

(1)

VIDEO OUT

COMPOSITE

OFF

×

ON

×

90H delay

90H delay

SDI OUT (1080i)

SD (480i, 576i)

SDI

OFF

×

(1)

ON

90H

advance

×

90H

advance

(2)

VIDEO OUT

COMPOSITE

Disabled

×

(1)

720P

SDI OUT (720P)

SD (480i, 576i)

SDI

OFF

×

(1)

ON

120H

advance

×

120H

advance

(2)

VIDEO OUT

COMPOSITE

Disabled

×

(1)

480i, 576i

SDI OUT (480i, 576i)

SD (480i, 576i)

SDI

Disabled

×

(1)

VIDEO OUT

COMPOSITE

Disabled

×

Connection diagram (1)

VTR, etc.

TC OUT

REF

SDI or

VIDEO OUT

AG-HPX500P/E

TC

HD signal

or

SD signal

TC IN

GENLOCK

Connection diagram (2)

Down-conversion

SD device

REF

TC

COMPOSITE

SDI

AG-HPX500P/E

TC

SD signal

(Delay)

TC IN

GENLOCK

Counter Setting and Display

Pressing the COUNTER button to view the counter
displays the counter value on the time code indicator
in the LCD and in the viewfinder. The counter value is
indicated in “Hour : Minute : Second” format.
The counter can display the total recording time but is
not displayed during playback.
The recording CTL counter value is retained also when
P2 cards are replaced and after a power down. At next
power up, the counter starts from the value reached at
the previous power down.

<Note>
• Pressing the RESET button when the counter value is

displayed resets the counter to 0.

• The counter value indicates values in the range

between 0:00:00 and 9:59:59 at 1-second step.