Battery setup screen – Panasonic AG-HPX500E User Manual

Page 127

Advertising
background image

127

Setup menu list

C

h

ap

te

r 7 M

en

u O
p

er

at

io

n

s

BATTERY SETUP screen

Item

Description of settings (Items in bold are factory settings.)

EXT DC IN SEL

/

Selects external DC power supply type.

AC ADPT: AC adapter

BATTERY: battery

BATTERY SELECT

/

Selects battery type.

PROPAC14, TRIMPAC14, HYTRON50, HYTRON140,

DIONIC90, DIONIC160, NP-L7, ENDURA7,

ENDURA10, ENDURA-D, PAG L95, BP-GL65/95, NICD14, TYPE A, TYPE B

BATTERY MODE

/

Near end setting

AUTO: Automatically selects one of the following battery types selected in BATTERY SELECT.

PROPAC14, TRIMPAC14, HYTRON50, HYTRON140, DIONIC90, DIONIC160, NP-L7, ENDURA7,
ENDURA10, ENDURA-D, PAG L95, BP-GL65/95

MANUAL: Manually enter near end voltage.

PROPAC14 NEAR

/

Sets near end voltage for PROPAC14 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.9 ... 15.0

TRIMPAC14 NEAR

/

Sets near end voltage for TRIMPAC14 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.6 ... 15.0

HYTRON50 NEAR

/

Sets near end voltage for HYTRON50 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.7 ... 15.0

HYTRON140 NEAR

/

Sets near end voltage for HYTRON140 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.1 ... 15.0

DIONIC90 NEAR

/

Sets near end voltage for DIONIC90 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.5 ... 15.0

DIONIC160 NEAR

/

Sets near end voltage for DIONIC160 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.0 ... 15.0

NP-L7 NEAR

/

Sets near end voltage for NP-L7 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.3 ... 15.0

ENDURA7 NEAR

/

Sets near end voltage for ENDURA7 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.4 ... 15.0

ENDURA10 NEAR

/

Sets near end voltage for ENDURA10 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.3 ... 15.0

ENDURA-D NEAR

/

Sets near end voltage for ENDURA-D (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.5 ... 15.0

PAG L95 NEAR

/

Sets near end voltage for PAG L95 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.5 ... 15.0

BP-GL65/95 NEAR

/

Sets near end voltage for BP-GL65/95 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.3 ... 15.0

NICD14 NEAR

/

Sets near end voltage for NICD14 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.9 ... 15.0

NICD14 END

/

Sets end voltage for NICD14 (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.5 ... 15.0

TYPE A FULL

/

Sets full voltage for TYPE A (Adjustable in 0.1 V units).

Adjustable range: 12.0 ...

15.7 ... 17.0

TYPE A NEAR

/

Sets near end voltage for TYPE A (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.5 ... 15.0

TYPE A END

/

Sets end voltage for TYPE A (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

12.8 ... 15.0

TYPE B FULL

/

Sets full voltage for TYPE B (Adjustable in 0.1 V units).

Adjustable range: 12.0 ...

16.0 ... 17.0

TYPE B NEAR

/

Sets near end voltage for TYPE B (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

13.1 ... 15.0

TYPE B END

/

Sets end voltage for TYPE B (Adjustable in 0.1 V units).

Adjustable range: 11.0 ...

12.5 ... 15.0

NEAR END CANCEL

/

Selects whether to cancel battery near end warning or not.

ON/OFF

When set to ON, the the flashing alarm and tally lamps can be stopped by pressing the DISP/MODE
CHK button.

Advertising