Maintenance, Cleaning inside the viewfinder, Eyepiece care – Panasonic AG-HPX500E User Manual

Page 141: Phenomenon inherent to ccd cameras, Charging the internal battery, Cleaning inside the viewfinder

Advertising
background image

141

Maintenance

C

h

ap

te

r 9 M

ain

te

n

an

ce a
n

d I

n

sp

ec

tio

n

s

Maintenance

Cleaning Inside the
Viewfinder

• Do not use thinner or other solvents to remove dirt

from the viewfinder.

• Wipe the lens with a commercially available lens

cleaner.

• DO NOT wipe the mirror. If dirt or rubbish is sticking

on the mirror, remove it with a commercially available
air blower.

Eyepiece Care

When the CRT screen and the mirror become dusty,
open the eyepiece to clean it.

<Note>
The mirror is provided with a special coating. Use
a blower or similar tool to remove dust from the
mirror. Using tissue paper will cause dust particles to
scrape against and damage the mirror surface. Use a
commercially available hair-planted cloth (such as a lens
cleaner) to remove more stubborn dirt.

Opening the eyepiece

Press the lock button.

Closing the eyepiece

Press the eyepiece until the lock button clicks into
place to close the eyepiece.

<Note>
When outdoors, never carry or set up the camera with
the eyepiece facing up to prevent sunlight, which could
damage the internal parts of the eyepiece.

Phenomenon Inherent to CCD
Cameras

Smears
• Smears may appear when shooting an object with

very high brightness.

• This phenomenon may appear more frequently as

the electronic shutter speed increases.

Charging the internal
battery

The internal battery preserves the date and time
settings. The appearance of in the viewfinder or
LCD monitor indicates that the internal battery is
exhausted.
Follow the steps below to recharge the battery.
Set the date and time when the battery has been fully
charged.

1

Connect the camera to an external
power source.

• Leave the POWER switch on the camera off.

2

Leave the camera for about 4 hours.

• This is the time it takes to fully charge the

internal battery.

• Check the time code and setting menus after

completing battery charging.

Replace the internal battery if appears after
charging. Consult your distributor.

Lock button

Eyepiece

Advertising