Arn expansion modules safety status, Synchronous cabling requirements, Table d-4 – Nortel Networks Passport ARN Routers User Manual

Page 145

Advertising
background image

Requirements for European Operation

114200-E Rev 00

D-3

ARN Expansion Modules Safety Status

ARN expansion modules are upgrade options that provide an additional
synchronous interface. These options can be installed in any ARN model.

Table D-4

lists the safety status of the interconnection point (COM3, COM4,

COM5, COM6, COM7, COM8, and COM9) provided by each of the expansion
modules (Order Nos. CV0004011, CV0004012, CV0004013, CV0004014,
CV0004015, CV0004026, and CV0004027) to the connection of other equipment.

Synchronous Cabling Requirements

Refer to Figures

D-1

through

D-6

and Tables

D-5

through

D-10

for serial interface

cabling information.

Note the following compliance requirements:

V.28 compliance requires an Order No. 7837 or 7934 cable.

V.35 compliance requires an Order No. 7220 or 7932 cable

X.21 compliance requires an Order No. 7224 or 7936 cable.

Table D-4.

Safety Status (Order Nos. CV0004011, CV0004012,
CV0004013, CV0004014, CV0004015, CV0004026,
CV0004027)

Port Location

Port Description

Type of Circuit

COM3, COM4, and COM5,
COM6, COM7, COM8, and
COM9

V.28, X.21, V.35

Telecommunications
network voltage (TNV) at
SELV levels

AUI

Ethernet AUI

SELV

10Base-T

Ethernet 10BASE-T

SELV

MAU

Token Ring

SELV

J2

Host Port

SELV

10/100BASE-T

Ethernet 10/100BASE-T

SELV

JB1

Host Port

SELV

Advertising