Status register 1, Status register 1 -25 – National Instruments AT-MIO-16X User Manual

Page 121

Advertising
background image

Chapter 4

Register Map and Descriptions

© National Instruments Corporation

4-25

AT-MIO-16X User Manual

Status Register 1

Status Register 1 contains 16 bits of AT-MIO-16X hardware status
information, including interrupt, analog input status, analog output
status, and data acquisition progress.

Address:

Base address + 18 (hex)

Type:

Read-only

Word Size:

16-bit

Bit Map:

Bit

Name

Description

15

DAQCOMP

Data Acquisition Complete—This bit
reflects the status of the data acquisition
termination signal. If DAQCOMP is set
and either OVERFLOW or OVERRUN
is also set, the current acquisition
sequence ended on an error condition.
If DAQCOMP is set and neither
OVERFLOW nor OVERRUN is set, the
data acquisition operation has completed
without error. When DAQCOMP is set,
and ADCREQ in Command Register 3 is
also set, enabled interrupt or DMA
requests are generated until the ADC
FIFO is empty. DAQCOMP is cleared by
strobing the DAQ Clear Register.

14

DAQPROG

Data Acquisition Progress—This bit
indicates whether a data acquisition
operation is in progress. If DAQPROG
is set, a data acquisition operation is in
progress. If DAQPROG is cleared, the

7

6

5

DACCOMP

4

3

DAQFIFOHF*

2

EEPROMDATA

1

0

EEPROMCD*

TMRREQ

DAQFIFOFF*

CFGMEMEF*

DAQFIFOEF*

15

MSB

LSB

14

13

DAQPROG

12

11

ADCFIFOEF*

10

DMATCB

9

8

OVERFLOW

DAQCOMP

ADCFIFOHF*

OVERRUN

DMATCA

Advertising