Table 4-10. analog output voltage versus digital c, Table 4-11. analog output voltage versus digital c, Table 4-10 – National Instruments AT-MIO-16X User Manual

Page 138: Table 4-11

Advertising
background image

Chapter 4

Register Map and Descriptions

AT-MIO-16X User Manual

4-42

© National Instruments Corporation

The formula for the voltage output versus digital code for a bipolar
analog output configuration in two’s complement form is as follows:

V

out

= V

ref

* (digital code)

32,768

where V

ref

is the positive reference voltage applied to the analog output

channel. The digital code in the preceding formula is a decimal value
ranging from –32,768 to +32,767.

Table 4-10. Analog Output Voltage Versus Digital Code (Unipolar Mode)

Digital Code

Voltage Output

Decimal

Hex

V

ref

= 10 V

0

0000

0.0 V

1

0001

152.6

µ

V

16,384

4000

2.5 V

32,768

8000

5.0 V

49,152

C000

7.5 V

65,535

FFFF

9.999847 V

Table 4-11. Analog Output Voltage Versus Digital Code (Bipolar Mode)

Digital Code

Voltage Output

Decimal

Hex

Reference = 10 V

–32,768

8000

–10.0 V

–32,767

8001

–9.999695 V

–16,384

C000

–5.0 V

–1

FFFF

–305.2

µ

V

0

0000

0.0 V

1

0001

305.2

µ

V

Advertising