Table b-1. signal connection descriptions, Table b-1 – National Instruments AT-MIO-16X User Manual

Page 236

Advertising
background image

Appendix B

I/O Connector

AT-MIO-16X User Manual

B-4

© National Instruments Corporation

Table B-1. Signal Connection Descriptions

68-Pin Pins

50-Pin Pins

Signal Names

Descriptions

24, 27, 29, 32,
56, 59, 64, 67

1-2

AI GND

Analog Input Ground—These pins are the
reference point for single-ended
measurements and the bias current return
point for differential measurements.

68, 33, 65, 30,
28, 60, 25, 57,
34, 66, 31, 63,
61, 26, 58, 23

3-18

ACH<0..15>

Analog Input Channels 0 through 15—In
differential mode, the input is configured for
up to eight channels. In single-ended mode,
the input is configured for up to 16 channels.

62

19

AI SENSE

Analog Input Sense—This pin serves as the
reference node when the board is in NRSE
configuration. If desired, this signal can be
programmed to be driven by the board
analog input ground in the DIFF and RSE
analog input modes.

22

20

DAC0 OUT

Analog Channel 0 Output—This pin
supplies the voltage output of analog
output Channel 0.

21

21

DAC1 OUT

Analog Channel 1 Output—This pin
supplies the voltage output of analog
output Channel 1.

20

22

EXTREF

External Reference—This is the external
reference input for the analog output
circuitry.

54, 55

23

AO GND

Analog Output Ground—The analog output
voltages are referenced to this node.

4, 7, 9, 12,13,
15, 18, 35, 36,
39, 44, 50, 53

24, 33

DIG GND

Digital Ground—This pin supplies the
reference for the digital signals at the I/O
connector as well as the +5 VDC supply.

52, 17, 49, 47

25, 27, 29, 31

ADIO<0..3>

Digital I/O port A signals.

19, 51, 16, 48

26, 28, 30, 32

BDIO<0..3>

Digital I/O port B signals.