Theory of Operation

AT-MIO-16X User Manual

3-26

© National Instruments Corporation

Figure 3-17. Timing I/O Circuitry Block Diagram

The Am9513A contains five independent 16-bit counter/timers, a 4-bit
frequency output channel, and five internally generated timebases. The
five counter/timers can be programmed to operate in several useful
timing modes. The programming and operation of the Am9513A are
presented in detail in Appendix C, AMD Am9513A Data Sheet.

The Am9513A clock input is one-tenth the BRDCLK frequency.
BRDCLK is selected through a register in the AT-MIO-16X register
set. The factory default for BRDCLK is 10 MHz, which generates a
1-MHz clock input to the Am9513A. The Am9513A uses this clock
input plus a BRDCLK divided-by-two input at Source 2 to generate
six internal timebases. These timebases can be used as clocks by the
counter/timers and by the frequency output channel. When BRDCLK
is 10 MHz, the six internal timebases normally used for AT-MIO-16X
timing functions are 5 MHz, 1 MHz, 100 kHz, 10 kHz, 1 kHz, and
100 Hz. The 16-bit counters in the Am9513A can be diagrammed as
shown in Figure 3-18.

GATE4

RTSI Bus

/
2

/
16

1 MHz

DATA<15..0>

Am9513A RD/WR

CONVERT

SCANCLK

CONFIGCLK

Data

Acquisition

Timing

SOURCE4
SOURCE3

OUT1
OUT2
OUT3
OUT4
OUT5

GATE3

Am9513A

Five-Channel

Counter/

Timer

GATE5

SOURCE5

OUT5

GATE2

OUT2

GATE1

SOURCE1

OUT1

FOUT

I/O Connector

EXTTRIG*

Flip

Flop

GATE4

PC I/O Channel

BRDCLK
(10 MHz)

ч

5

ч

2

SOURCE2

5 MHz

Advertising