Status Register 2

Status Register 2 contains 1 bit of AT-MIO-16X hardware status
information for monitoring the status of the A/D conversion.

Address:

Base address + 1A (hex)

Type:

Read-only

Word Size:

1-bit

Bit Map:

Bit

Name

Description

15-1

X

Don’t care bits.

0

ADC_BUSY*

ADC BUSY—This bit indicates the
status of the A/D converter on the
AT-MIO-16X during a conversion or
calibration process. The A/D converter
on the AT-MIO-16X can calibrate its
internal circuitry on command by
strobing the ADC Calibration Register.
If ADC_BUSY* is clear, an ADC
conversion or calibration operation is
currently in progress. If ADC_BUSY* is
set, no ADC conversion or calibration
operation is in progress. An ADC
calibration cycle takes approximately
1.25 sec. During this time, the ADC is
busy as reflected by the ADC_BUSY*
status, and cannot be used.