External strobe register, External strobe register -61 – National Instruments AT-MIO-16X User Manual

Page 157

Advertising
background image

Chapter 4

Register Map and Descriptions

© National Instruments Corporation

4-61

AT-MIO-16X User Manual

External Strobe Register

Accessing the External Strobe Register location generates an active low
signal at the EXTSTROBE* output of the I/O connector. This signal has
a minimum low time of 500 nsec. The EXTSTROBE* pulse is useful
for several applications, including generating external general-purpose
triggers and latching data into external devices, for example, from the
digital output port.

Address:

Base address + 1E (hex)

Type:

Write-only

Word Size:

8-bit

Bit Map:

Not applicable, no bits used

Strobe Effect:

Generates an active-low pulse at the I/O connector of
at least 500-nsec duration