Warning – Quadra-Fire Castile Pellet Insert CASTILEI-MBK User Manual

Page 10

Advertising
background image

Page 10

7022-122

January 19, 2011

R

Castile Pellet Insert

Fire Risk.
Comply with all minimum clear-

ances to combustibles as speci-

fi ed.

WARNING

Failure to comply may cause

house fi re.

NOTE:

Illustrations refl ect typical installations

and are FOR DESIGN PURPOSES

ONLY.

Illustrations/diagrams are not drawn to

scale.

Actual installation may vary due to

individual design preference.

A

C

B

D

C

B

0 in. Clearance To Exposed Section And Face Trim

B. Clearance To Combustibles, UL and ULC

Inches

Millimeters

A

Top of Hopper

Top Vent

2.0

51

Rear Vent

2.5

64

B

Side of Hopper

Top or Rear Vent

2.0

51

C

Back of Hopper

Top or Rear Vent

4.0

102

D

Vent Pipe to Combustible

Top or Rear Vent

3.0

76

12 in

(305mm)

Combustible

Mantel

6 in

(152mm)

Outside Air

Top Vent:

2 in. (51mm)
Rear Vent:

2.5 in (64mm)

Back of Hopper:

4 in (102mm)
Vent Pipe to

Combustibles:

3 in (76mm)

INSTALLED AS A BUILT-IN UNIT

Shown with Rear Vent and Outside Air

Figure 10.1

Figure 10.2

AS A BUILT-IN

NOTE:

All Clearances are Minimum Clearances

Must be installed in a non-tapered enclosure.