Maintaining & servicing your appliance, Caution, C. general maintenance – Quadra-Fire Castile Pellet Insert CASTILEI-MBK User Manual

Page 32: A. proper shutdown procedure, Castile pellet insert

Advertising
background image

Page 32

7022-122

January 19, 2011

R

Castile Pellet Insert

10

Maintaining & Servicing Your Appliance

C. General Maintenance

1. Types of Fuel

Depending on the type of fuel you are burning will dictate how

often you have to clean your fi repot.
If the fuel you are burning has a high dirt or ash content or you

are burning shelled fi eld corn, it may be necessary to clean the

fi repot more than once a day.
Dirty fuel will cause clinkers to form in the fi repot. A clinker is

formed when dirt, ash or a non-burnable substance is heated

to 2000F (1093C) and becomes glass-like. See “

D” page 36

in this section for more details on fuels with high ash content.

Clinker

Figure 32.1 - Clinker

Shock and Smoke Hazard
• Turn down thermostat, let appliance completely

cool and exhaust blower must be off. Now you

can unplug appliance before servicing.

• Smoke spillage into room can occur if appliance

is not cool before unplugging.

• Risk of shock if appliance not unplugged before

servicing appliance.

CAUTION

A. Proper Shutdown Procedure

B. Quick Reference Maintenance Chart

Follow the detailed instructions found in this

section for each step listed in the chart below.

Cleaning or Inspection

Frequency

Daily Weekly Monthly Yearly

Ash Pan

Every 5 bags of fuel depend-

ing on the fuel type or ash

build-up

OR

X

Ash Removal from Firebox

Every 5 bags or more fre-

quently depending on the fuel

type or ash build-up

OR

X

Beneath Heat Exchanger

Every 1 ton of fuel

OR

X

Blower, Combustion (Exhaust)

More frequently depending on

the fuel type

OR

X

Blower, Convection

Every 25 bags or more fre-

quently depending on the fuel

type

OR

X

Door Latch Inspection

Prior to heating season

OR

X

Exhaust Path

More frequently depending on

ash build-up

OR

X

Firebox - Prepare for Non-Burn Season At end of heating season

OR

X

Firepot - Burning pellets - hardwood

Every 3 bags

OR

X

Firepot - Burning pellets - softwood

Every 5 bags

OR

X

Firepot - Burning Corn

Every 1 bag

OR

X

Glass

When clear view of fi repot

becomes obscure

OR

X

Heat Exchanger & Drop Tube

Every 5 bags of fuel

OR

X

Hopper

Every 50 bags of fuel or when

changing fuel types

OR

X

Top Vent Adapter

More frequently depending on

the fuel type or ash build-up

OR

X

Venting System

More frequently depending on

the fuel type

OR

X

NOTICE: These are recommendations. Clean more frequently if you encounter heavy build-up of ash at

the recommended interval or you see soot coming from the vent. Not properly cleaning your

appliance on a regular basis will void your warranty.