Location of the appliance and chimney will affect

performance.
• Install through the warm airspace enclosed by the building

envelope. This helps to produce more draft, especially

during lighting and die-down of the fi re.

• Penetrate the highest part of the roof. This minimizes the

effects of wind loading.

• Locate termination cap away from trees, adjacent

structures, uneven roof lines and other obstructions.

• Minimize the use of chimney offsets.
• Consider the appliance location relative to fl oor and ceiling

and attic joists.

B. Locating Your Appliance & Chimney

D. Negative Pressure

WARNING! Risk of Asphyxiation! Negative pressure can
cause spillage of combustion fumes and soot.

Negative pressure results from the imbalance of air avail-

able for the appliance to operate properly. It can be stron-

gest in lower levels of the house.
Causes include:
• Exhaust fans (kitchen, bath, etc.)
• Range hoods
• Combustion air requirements for furnaces, water heaters

and other combustion appliances

• Clothes dryers
• Location of return-air vents to furnace or air conditioning
• Imbalances of the HVAC air handling system
• Upper level air leaks such as:
- Recessed lighting
- Attic hatch
- Duct leaks
To minimize the effects of negative air pressure:
• Install the outside air kit with the intake facing prevailing

winds during the heating season

• Ensure adequate outdoor air for all combustion appliances

and exhaust equipment

• Ensure furnace and air conditioning return vents are not

located in the immediate vicinity of the appliance

• Avoid installing the appliance near doors, walkways or

small isolated spaces

• Recessed lighting should be a “sealed can” design
• Attic hatches weather stripped or sealed
• Attic mounted duct work and air handler joints and seams

taped or sealed

C. Draft

Draft is the pressure difference needed to vent appliances

successfully. When an appliance is drafting successfully, all

combustion byproducts are exiting the home through the

chimney.
Considerations for successful draft include:
• Preventing negative pressure
• Location of appliance and chimney
To measure the draft or negative pressure on your appliance

use a magnahelic or a digital pressure gauge capable of

reading 0 - .25 inches of water column (W.C.).
The appliance should be running on high for at least 15

minutes for the test.
With the stove running on high you should have a negative

pressure equal to or greater than the number given in the

chart below. If you have a lower reading than you fi nd on the

chart, your appliance does not have adequate draft to burn

the fuel properly.

CAUTION

• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE

SERVICING ANOTHER APPLIANCE.

• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT

OR SYSTEM.

May allow fl ue gases to enter the house

Minimum Vacuum Requirements:

.095

NOTICE: Hearth & Home Technologies assumes no

responsibility for the improper performance of the chimney

system caused by:
• Inadequate draft due to environmental conditions
• Downdrafts
• Tight sealing construction of the structure

• Mechanical exhausting devices