Quadra-Fire Castile Pellet Insert CASTILEI-MBK User Manual

Page 37

Advertising
background image

R

January 19, 2011

7022-122

Page 37

Castile Pellet Insert

F. Convection Blower Replacement

1. The blower is located at the bottom rear of the insert.

If an outside air kit is also installed, you will fi rst need

to remove the outside air fl ange by removing the 2

screws using a Phillips head screwdriver. You do not

need to remove the fl ex pipe from the fl ange.

2. If you have adequate clearance you will not have to

remove the panel set and disconnect fl ue, if not then

you will have to remove the panel set and disconnect

the fl ue.

3. Pull appliance out onto the hearth.
4. Remove left cast side.

5. Disconnect the wires from the blower. The wires

coming from the wiring harness are purple & white and

the wires from the blower are black.

6. The blower is held in place with a wing screw.
7. Re-install in reverse order.

Wing Screw

E. Combustion Blower Replacement

1. If you have adequate clearance you will not have to

remove the panel set and disconnect fl ue, if not then

you will have to remove the panel set and disconnect

the fl ue.

2. Pull appliance out onto the hearth.
3. Remove right cast side.
4. Disconnect the white and blue wires from the blower.
5. Remove blower mounting screws (not housing bolts),

Figure 37.1, from blower housing and remove blower.

The replacement blower is shipped with a housing.

If you do not need the housing, discard it. If you do

need to the replace the housing you will also need

to replace the gasket. See Service Parts List for the

part number.

6. Re-install in reverse order.

Figure 37.1

Figure 37.2

Housing Bolts

(Do Not Remove)

Blower

Screws

Advertising