Mobile home, Warning, Caution – Quadra-Fire Castile Pellet Insert CASTILEI-MBK User Manual

Page 17

Advertising
background image

R

January 19, 2011

7022-122

Page 17

Castile Pellet Insert

6

Mobile Home

1. An outside air inlet must be provided for the combustion

air and must remain clear of leaves, debris, ice and/or

snow. It must be unrestricted while the appliance is

in use to prevent room air starvation which causes

smoke spillage. Smoke spillage can also set off smoke

alarms.

2. The combustion air duct system must be made of

metal. It must permit zero clearance to combustible

construction and prevent material from dropping into

the inlet or into the area beneath the dwelling and

contain a rodent screen.

3. The appliance must be secured to the mobile home

structure by bolting it to the fl oor (using lag bolts). Use

the same holes that secured the appliance to the ship-

ping pallet with a minimum of two attachment points.

4. The appliance must be grounded with #8 solid copper

grounding wire or equivalent, terminated at each end

with an NEC approved grounding/bonding connector.

5. Refer to clearances to combustibles and fl oor protection

requirements on

pages 9 to 11 for listings to combus-

tibles and appropriate chimney systems.

6. Use silicone to create an effective vapor barrier at

the location where the chimney or other component

penetrates to the the exterior of the structure.

7. Follow the chimney manufacturer’s instructions when

installing the vent system for use in a mobile home.

8. Installation shall be in accordance with the Manufactur-

ers Home & Safety Standard (HUD) CFR 3280, Part

24.

Installation must comply with Manufactured Home and

Safety Standard (HUD), CFR 3280, Part 24.

WARNING

You must use a Quadra-Fire Outside Air Kit for instal-

lation in a mobile home.

A. Mobile Home Installation

Figure 16.1

Spark Arrestor Cap

Roof Flashing

Storm Collar

Joist Shield/Firestop

Approved Class “L” o
“PL” Pellet Vent

CAUTION

THE STRUCTURAL INTEGRITY OF THE MANUFAC-

TURED HOME FLOOR, WALL AND CEILING/ROOF MUST

BE MAINTAINED.

Do NOT cut through:

• Floor joist, wall, studs or ceiling trusses.

• Any supporting material that would affect the structural

integrity.

NEVER INSTALL IN A SLEEPING ROOM.
Consumes oxygen in the room.

WARNING

Asphyxiation Risk.