7022-122

January 19, 2011

R

Castile Pellet Insert

have been obtained.
16. Thermostat
The appliance is designed to run on a 12 volt AC thermostat.

The heat anticipator, if present, should be set on the lowest

setting available.
17. Snap Disc #1 (Convection Blower) 110°F
Snap disc #1 is located on the right side of the fi rebox. There

are 2 purple wires connected to it. This snap disc turns the

convection blower on and off as needed. Power is always

present at snap disc #1 if the stove is powered up.
18. Snap Disc #2 (Fuel Delivery Interrupt) 250°F
Snap disc #2 is located on the back side of the feed drop

tube. There is 1 orange wire and 1 black wire connected to

it. This snap disc will turn off the feed system, which will turn

off the appliance if an overfi re condition should occur or if the

convection blower should fail to operate. If this occurs the

Thermocouple

Burn

Selector

Thermostat

Block

Igniter

Call

Light

Snap

Disc #3

Reset

Button

Fuse

Snap

Disc #1

Exhaust

Blower

Convection

Blower

Vacuum

Switch

Snap

Disc #2

Capacitor

Feed

Motor

Yellow

Blue

Gray

Black

Black

Black

Black

Black

White

White

Red

Red

Purple

Red

Hopper

Switch

snap disc with automatically reset itself.
19. Snap Disc #3 (Burn Back Protector) 250°F
Snap disc #3 is mounted on the back of the auger tube in the

center of the appliance and has a reset button. To access

it remove the right side panel. If the fi re tries to burn back

into the feed system or push exhaust up the feed tube, this

snap disc will shut the entire system off. This disc must be

manually reset. Power is always present at snap disc #3 if

the stove is powered up.
20. Vacuum Switch
The vacuum switch is located on the lower right side of the

appliance behind left access panel. This switch turns the

feed system on when vacuum is present in the fi rebox. The

vacuum switch is a safety device to shut off the feed motor if

the exhaust or the heat exchanger system is dirty or plugged

or if the fi rebox door is open.
21. Wiring Schematic

See Figure 42.1 below

Figure 42.1