Warning, Castile pellet insert c. pellet venting charts, Figure 14.1 – Quadra-Fire Castile Pellet Insert CASTILEI-MBK User Manual

Page 14

Advertising
background image

Page 14

7022-122

January 19, 2011

R

Castile Pellet Insert

C. Pellet Venting Charts

Figure 14.1

Fire Risk.
• Only LISTED venting components may be

used.
• NO OTHER vent components may be used.

Substitute or damaged vent components may

impair safe operation.

WARNING

The maximum horizontal venting allowed with no vertical vent-

ing attached is 48 inches (1219mm) including one 90° elbow

or two 45° elbows. This is our recommended horizontal vent-

ing installation. Addition of any horizontal venting beyond

48 inches (1219mm) Hearth & Home Technologies strongly

recommends a minimum of 60 inches (1524mm) of additional

vertical vent. Horizontal sections of vent pipe should have a

1/4 inch (6.35mm) rise per foot.

Hearth & Home Technologies recommends any installation

requiring more than two 90° elbows, or more than 15 feet

(4.5m) of venting to use 4 inch (102mm) vent.

NOTICE: These are guidelines for successful venting of your pellet appliance. The more vertical rise you can obtain in

your system, the better it will perform. Horizontal vent runs can accumulate ash and will need to be cleaned more often.

Try to keep them as short as possible.

ONE 90º ELBOW

Total

Horizontal

Minimum

Vertical

Vent

Diameter

4

0

3

5

5

3

6

6

3

7

7

3

8

8

4

9

9

4

10

10

4

11

11

4

12

12

4

13

13

4

14

14

4

15

15

4

16

16

4

17

17

4

18

18

4

19

19

4

TWO 90º ELBOWS

Total

Minimum

Vent

Horizontal

Vertical

Diameter

2

5

3

3

6

3

4

7

3

5

8

3

6

9

3

7

10

4

8

11

4

9

12

4

10

13

4

11

14

4

12

15

4

13

16

4

14

17

4

15

18

4

THREE 90º ELBOWS

Total

Minimum

Vent

Horizontal

Vertical

Diameter

2

11

4

3

12

4

4

13

4

5

14

4

6

15

4

7

16

4

8

17

4

9

18

4

10

19

4

11

20

4

Figure 14.2

Figure 14.3

45° elbow is equivalent to 1 foot of straight pipe

90° elbow is equivalent to 3 feet of straight pipe

Minimum Vertical Vent for One Elbow

0

5

10

15

20

0

5

10

15

20

Horizontal Run, (ft)

M

in

im

um

V

er

tic

al R

is

e

(ft

)

Minimum Vertical Vent for Two Elbows

0

5

10

15

20

0

5

10

15

Length of Horizontal Sections, (ft)

M

in

im

um

V

er

tic

al

R

is

e,

(f

t)

Minimum Vertical Vent for Three Elbows

0

5

10

15

20

25

0

2

4

6

8

10

12

Length of Horizontal Sections (ft)

M

in

im

um

V

er

tic

al R

is

e

(ft

)

Minimum Vertical Vent for One Elbow

Minimum Vertical Vent for Two Elbows

Minimum Vertical Vent for Three Elbows

Horizontal Run (FT)

Length of Horizontal Sections (FT)

Length of Horizontal Sections (FT)

Advertising