Venting systems, Caution, Warning – Quadra-Fire Castile Pellet Insert CASTILEI-MBK User Manual

Page 15

Advertising
background image

R

January 19, 2011

7022-122

Page 15

Castile Pellet Insert

5

Venting Systems

NOTE:

In Canada, where passage through a wall or partition of

combustible construction is desired, the installation shall

conform to CAN/CSA-B365.

Figure 15.1

CAUTION

Never draw outside combustion air from:

• Wall, fl oor or ceiling cavity

• Enclosed space such as an attic or garage

NOTE:

Illustrations refl ect typical installations and are FOR

DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design

preference.

A. Full Reline With Horizontal Outside Air

Outside Air through Rear

Wall (Horizontal)

NOTE; Use metal plate around

exhaust vent pipe and seal all

edges with non-flammable insu-

lation such as , mineral wool or

ceramic.

Do not use high temperature

caulking materials to seal any

edge to prevent future service-

ability.

Figure 15.1

Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be a minimum 6 inch

(152mm) UL103 HT.

WARNING