G. Removing Metal Floor of Factory-Built Fireplace

• The fi rebrick (refractory), glass doors, screen rails, screen

mesh and log grates can be removed from a factory-built fi re-

box in order to gain minimum insert opening requirements.

• Any smoke shelves, shields and baffl es may be removed

from a factory-built fi rebox if attached with mechanical fas-

teners.

• The metal fl oor of the factory-built fi replace may be removed

to facilitate the installation of the insert only when a 1/4 (6mm)

inch airspace is provided between the insert and the fl oor of

outer wrap.

• This should have prior approval from authority having juris-

diction. Upon removal, the factory built fi replace is no longer

considered a UL 127 Listed fi replace, only a metal box.

• Ensure the metal box is supported to hold weight of the chim-

ney and the insert. Maintain clearances to combustibles.

Figure 12.1. Measure and mark the metal fl oor for cutting. With

a drill, make a starter hole in each corner.

Figure 12.2. Using a saws-all, cut out the fl oor.

In Figure 2.3 Ensure that the power cord can not be damaged

by the sharp metal edge. You may need to cut out a notch to

accommodate the cord.

The following is only one example as there are many different

models of factory-built fi replaces.

NOTE: If the fl oor is made of thin metal, we recommend

using the 2 x 4 from the insert packaging to support the insert.

The 2 x 4 may need to be cut to the appropriate size. Ensure

that the leveling bolt is positioned over the 2 x 4 before level-

ing the insert.

The fireplace must not be altered, except for the

exceptions listed below. Do not removal the bricks and

mortar from the existing fi replace.

The following modifi cations are premissible:
• Removal of damper or locked in open position

• Removal of smoke shelf or baffl e

• Removal of ember catches

• Removel of fi re grate

• Removal of view screen/curtain

• Removal of doors
• External trim pieces which do not affect the operation

of the fi replace may be removed providing they can be

stored on or within the fi replace for reassembly if the

insert is removed.

• The permanent metal warning label provided must be

attached to the back of the fi replace, with screws or

nails, stating that the fi replace may have been altered

to accommodate the insert, and the fi replace must be

returned to original condition befor use as a conventional

fi replace.

Figure 12.4.

• If the hearth extension is lower than the fireplace

opening, the portion of the insert extending onto the

hearth must be supported.

• Manufacturer designed adjustable support kit can be

ordered from your dealer.

• Final approval of this installation type is contingent upon

the authority having jurisdiction.

H. Altering the Factory-Built Fireplace

NOTE: Refer to chimney liner manufacturer for rec-

ommendations on supporting the liner. Installation

into fi replaces without a permit will void the listing

250-2061

WARNING

THIS FIREPLACE MAY HAVE BEEN ALTERED

TO ACCOMMODATE AN INSERT. IT MUST BE

RETURNED TO ITS ORIGINAL CONDITION

BEFORE USE AS A SOLID FUEL BURNING

FIREPLACE.

250-2061