Castile Pellet Insert

C. Full Reline With Vertical Outside Air

Figure 16.1

Outside Air

Termination

at

Chimney Top

12” (305mm)

min. below

12” (305mm)

min. above

NOTE; Use metal

plate around

exhaust vent pipe

and seal all edges

with non-flammable

insulation such as

mineral wool or

ceramic.

Do not use high

temperature caulk-

ing materials to seal

any edge to prevent

future serviceability

NOTE: Check clearances carefully for this type of

installation to ensure adequate room for outside air

venting.

Check building codes prior to installation.

• Installation MUST comply with local, regional, state and

national codes and regulations.

• Consult local building, fi re offi cials or authorities having

jurisdiction about restrictions, installation inspection,

and permits.

CAUTION

NOTE: In Canada, only a full reline is allowed per

ULC S628-93, ORD ULC C1482-M1990.

NOTE: In Canada this fi replace insert must be installed

with a continous chimney liner a 6 inch (152mm) in

diameter extending from the fi replace insert to the top

of the chimney. The chimney liner must conform to the

Class 3 requirments of CAN/ULC-S635, Standard for

Lining Systems for Existing Masonry or Factory-Built

Chimneys and Vents, or CAN/ULC-S640, Standard for

Lining Systems for New Masonry Chimneys.