Caution, Warning, Vent information – Quadra-Fire Castile Pellet Insert CASTILEI-MBK User Manual

Page 13

Advertising
background image

R

January 19, 2011

7022-122

Page 13

Castile Pellet Insert

Do not terminate vent in any enclosed or semi-enclosed

area such as a carport, garage, attic, crawl space, under a

sun deck or porch, narrow walkway or closely fenced area,

or any location that can build up a concentration of fumes

such as a stairwell, covered breezeway, etc.

CAUTION

Vent surfaces get HOT, can cause burns if

touched. Non-combustible shielding or guards

may be required.

WARNING

4

Vent Information

A. Chimney and Exhaust Connection

1. Chimney & Connector: Use 3 or 4 inch (76-102mm)

diameter type "L" or "PL" venting system. It can be vented

vertically or horizontally.

2. Mobile Home: Approved for all Listed pellet vent. Use Listed

double wall fl ue connector. A Quadra-Fire outside air kit must

be used with manufactured home installations.

3. Residential: Use 24 gauge single wall fl ue connector or

Listed double wall fl ue connector to Class A Listed metal

chimneys, or masonry chimneys meeting International Build-

ing Code (ICC) standards for solid fuel appliances.

4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE

VENT MANUFACTURER.

5. Secure exhaust venting system to the appliance with at least

3 screws. Also secure all connector pipe joints with at least

3 screws through each joint.

6. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST

VENTING SYSTEM OF THIS UNIT.

7. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE

SERVING ANOTHER APPLIANCE.

NOTE: All pipe must be welded seam pipe whenever pos-

sible. Seal pipe joints with high temperature silicone (500°F

[260°C] minimum rated only).
NOTE: If burning shelled fi eld corn, you must use approved

venting specifi cally designed for corn. Follow the instruc-

tions from the venting manufacturer.

Fire Risk.
• Only LISTED venting components may be used.
• NO OTHER vent components may be used.

Substitute or damaged vent components may impair

safe operation.

Follow venting manufacturer’s clearances

and instructions when installing venting system.

WARNING

B. Venting Termination Requirements

1

. Termination must exhaust above air inlet elevation. It

is strongly recommended that at least 60 inches

(1524mm) of vertical pipe be installed when appli-

ance is vented directly through a wall. This will create

a natural draft, which will help prevent the possibility of

smoke or odor venting into the home during a power

outage. It will also keep exhaust from causing a nui-

sance or hazard by exposing people or shrubs to high

temperatures. The safest and preferred venting method

is to extend the vent vertically through the roof.

2

. Distance from doors and opening windows, or gravity or

ventilation air inlets into building:
a. Not less than 48 inches (1219mm) below;

b. Not less than 48 inches (1219mm) horizontally

from;

c. Not less than 12 inches (305mm) above.

3. Distance from permanently closed windows:

a. Not less than 12 inches (305mm) below, horizontally

from or above.

4

. Distance between bottom of termination and grade

should be 12 inches (305mm) minimum. This is con-

ditional upon plants in the area, and nature of grade

surface. The grade surface must be a non-combustible

material (i.e., rock, dirt). The grade surface must not be

lawn. Distance between bottom of termination and public

walkway should be 84 inches (2134mm) minimum.

5

. Distance to combustible materials must be 24 inches

(610mm) minimum. This includes adjacent buildings,

fences, protruding parts of the structure, roof overhang,

plants and shrubs, etc.

6. Termination Cap Location (Home Electrical Service)

• Side-to-side clearance is to be the same as minimum

clearance to vinyl inside corners.

• Clearance of a termination cap below electrical service

shall be the same as minimum clearance to vinyl sof-

fi ts.

• Clearance of a termination cap above electrical service

will be 12 inches (305mm) minimum.

• Location of the vent termination must not obstruct or

interfere with access to the electrical service.

NOTICE:

In Canada when using a factory-built chim-

ney it must be safety listed, Type UL103 HT (2100

o

F)

[1149

o

C] CLASS “A” or conforming to CAN/ULC-

S629M, STANDARD FOR 650

o

C FACTORY-BUILT

CHIMNEYS.