shut off power to the appliance.
7. Heat Exchangers
The heat exchangers transfer heat from the exhaust system

into convection air. There are 2 clean out rods located under

the heat exchangers.
8. Heat Output Switch
The heat output switch is located on the lower right side of

fi rebox, behind the front access door and above the reset

button. The function of the heat output switch is to regulate

the burn rates; low, medium and high settings.
9. Hopper Switch
The hopper switch is located in the upper right hand corner,

outside of the hopper. This switch is designed to shut down

the feed motor whenever the hopper lid is opened.
10. Igniter
The igniter is mounted on the base of the fi repot. Combustion

air travels over the red hot igniter creating super heated air

that ignites the pellets.
11. Junction Box And Wiring Harness
The junction box is located on the lower right side of the

appliance, behind the left front access door. The junction box

and wiring harness are replaced as one component.
12. Power Supply
The power outlet is located on the lower right side of the

appliance on the front of the junction box. Check the wall

receptacle for 120 volt, 60 Hz (standard current). Make sure

the outlet is grounded and has the correct polarity. A good

surge protector is recommended. When operating with a

generator you need a least 600 watts of power, or with an

inverter at least 800 watts of power available for the appliance

during the start cycle.
13. Red Call Light
The red call light is on the top of the junction box by the

fuse. The function of the red call light is to indicate that the

thermostat is calling for heat.
14. Reset Button
The reset button is located on the lower right side of fi rebox

in behind the access door and below the heat output control

switch. The function of the switch is to momentarily open the

thermostat circuit, which restarts the system.
15. Thermocouple
The thermocouple is located on top of the fi repot inside

the thermocouple cover (ceramic protection tube). The

thermocouple sends a millivolt signal to the control box

indicating the preset temperatures of the green and red lights

When describing the location of a component

part it is always AS YOU FACE THE FRONT

OF THE APPLIANCE.

2. Convection Blower
The convection blower is mounted at the bottom rear of the

appliance. There are 2 impellers, one on each side of the

motor. The convection blower pushes air through the heat

exchange system into the room.
3. Exhaust Blower
The exhaust blower is mounted on the right side of the

appliance behind the right side panel. The exhaust blower

is designed to pull the exhaust from the appliance and push

it out through the venting system.
4. Feed System
The feed system is located behind the fi rebox and can be

removed as an entire assembly. The assembly includes

the feed motor, mounting bracket, bearing and feed spring

(auger). The hollow feed spring (auger) pulls pellets up the

feed tube from the hopper area and drops them down the

feed chute into the fi repot at a set rate. The feed motor starts

and stops every 7 seconds.
5. Firepot

The fi repot is made of high quality ductile iron and has a

cleaning pull-out rod. The fl oor of the fi repot opens for

cleaning when you pull out the rod. Be sure that the fl oor

returns to a completely closed position or your appliance

will not operate properly.
6. Fuse
The fuse is located on the side of the junction box near the

red call light. The fuse will blow should a short occur and

NOTE:

Do

NOT open the control box. This will void the

warranty. If you need to plug in or remove the control

box you must fi rst

unplug the appliance.

1. Control Box
a. The control box is located on lower right side of

appliance, on top of the junction box.

b. There is a light located inside of the control box. The

internal light will turn green when the appliance has

reached a temperature of 200

F (93C) in the fi repot.

and will turn red when it reaches 600

o

F (315C).

c. There is also an internal blue light located in the upper

left corner of the control box. When you plug in the

appliance the blue light will automatically start blinking

4 blinks every 10 seconds for 60 seconds (depending

upon setting) and then will stop.