Castile Pellet Insert

A

B

C

D

D. Minimum Opening for Masonry and

Factory-Built Fireplaces

Inches

Millimeters

A

Insert side to combustible side wall

16

406

B

Insert top to mantel

12

305

C

Insert top to maximum. 2-1/4 inch

(57mm) face trim

4-3/4

121

D

Insert side to maximum. 2-1/4 inch

(57mm) face trim

10

254

Location

Inches

Millimeters

A

Rear Width

23-5/8

600

B

Depth

17

432

C

Height

21-1/4

540

D

Front Width

28-1/8

714

Figure 11.1

C. Masonry and Factory-Built Fireplaces

Inches

Millimeters

E Floor protection hearth extension from

door opening

6

152

F

Floor protection to the side of door

opening

6

152

E. Floor Protection

Figure 11.2

Side W

all

Mantel

Maximum Mantel Depth: 12 inches (305mm)

Face

Trim

E

F

A

D

C

B

F. Prefabricated Metal Chimney

The chimney can be new or existing, masonry or prefabricated

and must meet the following minimum requirements:
• Must be minimum 6 inch (152mm) inside diameter of

high temperature chimney listed to UL 103 HT (2100

o

F)

or ULC-S628.

• Must use components required by the manufacturer for

installation.

• Must maintain clearances required by the manufacturer

for installation.

• Refer to manufacturers instructions for installation
•This insert is listed to UL 1482 Standard and is approved

for installation into listed factory-built zero clearance fi re-

places listed to UL 127 conforming to the following speci-

fi cations and instructions:

•The original factory-built zero clearance fi replace chim-

ney cap must be re-installed after installing the approved

chimney liner meeting type UL 103 HT requirements

(2100°F) per UL 1777.

•If the chimney is not listed as meeting HT requirements,

or if the factory built fi replace was tested prior to 1998, a

full height listed chimney liner must be installed from the

appliance fl ue collar to the chimney top.

•The liner must be securely attached to the insert fl ue collar

and the chimney top.

•The air fl ow of the factory-built zero-clearance fi replace

system must not be altered. The fl ue liner top support

attachment must not reduce the air fl ow for the existing

air-cooled chimney system.

•No dilution air is allowed to enter the chimney.

1. Secure the fi replace damper in the open position. If

this cannot be accomplished, it will be necessary to

remove the damper.

2. Seal damper area of chimney around chimney

connector with a high temperature sealant or seal

insert against the face of the fi replace.

3. Both methods must be removable and replaceable

for cleaning and re-installation.