Jksss+ series 2.3 - 4.2kv, Menu, Mp.3 rtd values (metering page 3) – Toshiba VF010H05 User Manual

Page 81

Advertising
background image

JKSSS+ Series - 75

JKSSS+ Series

2.3 - 4.2KV

HOTTEST STATOR
RTD#: # @ ### C

HOTTEST NON-STATOR
RTD#: # @ ### C

STATOR PHASE C1
RTD #5: ### C = ### F

STATOR PHASE C2
RTD #6: ### C = ### F

MAX TEMP SINCE
CLEAR RTD #5: ### C

MAX TEMP SINCE
CLEAR RTD #6: ### C

END BEARING
RTD #7: ### C = ### F

SHAFT BEARING
RTD #8: ### C = ### F

MAX TEMP SINCE
CLEAR RTD #7: ### C

MAX TEMP SINCE
CLEAR RTD #8: ### C

RTD #9
RTD #9: ### C = ### F

MAX TEMP SINCE
CLEAR RTD #9: ### C

STATOR PHASE A1
RTD #1: ### C = ### F

STATOR PHASE A2
RTD #2: ### C = ### F

MAX TEMP SINCE
CLEAR RTD #1: ### C

MAX TEMP SINCE
CLEAR RTD #2: ### C

STATOR PHASE B1
RTD #3: ### C = ### F

STATOR PHASE B2
RTD #4: ### C = ### F

MAX TEMP SINCE
CLEAR RTD #3: ### C

MAX TEMP SINCE
CLEAR RTD #4: ### C

MENU

METERING PAGE 3
RTD VALUES

Screen 1

Screen 2

Screen 3

Screen 4

Screen 5

Screen 6

Screen 7

Screen 8

Screen 9

Screen 10

Screen 11

Screen 12

Screen 13

Screen 14

Screen 15

Screen 16

Screen 17

Screen 18

Screen 19

Screen 20

Screen 21

Screen 22

Screen 23

Screen 24

Screen 25

Screen 27

Screen 28

Screen 29

Screen 26

PRESS ENTER TO
CLEAR MAX TEMP REGS

MEASURED RUN COOL
TIME: ### MIN

MEASURED STOPPED
COOL TIME: ### MIN

RTD #10
RTD #10: ### C = ### F

MAX TEMP SINCE
CLEAR RTD #10: ### C

RTD #11
RTD #11: ### C = ### F

RTD #12
RTD #12: ### C = ### F

MAX TEMP SINCE
CLEAR RTD #11: ### C

MAX TEMP SINCE
CLEAR RTD #12: ### C

MP.3 RTD Values (Metering Page 3)

Displays the RTD information.

Screen 1: Displays the hottest stator RTD (#1 - 6

depending upon number of RTDs used for

stator).

Screen 2: Displays the hottest non-stator RTD (#7-12 if

#1-6 is used for stator).

Screen 3: Displays the temperature of stator phase A1

in °C and °F.

Screen 4: Displays the maximum temperature for

RTD #1 since the last command to clear the

thermal register.

Screen 5 - 26: Same as Screens 3 - 4 for RTDs #2-12.

Screen 27: Allows the user to clear the maximum

temperature register upon entering the

setpoint level 3 password.

Screen 28: Displays the measured run cool time in

minutes.

Screen 29: Displays the measured stopped cool time in

minutes.

Advertising