Jksss+ series 2.3 - 4.2kv, Menu, Mp.7 statistics (metering page 7) – Toshiba VF010H05 User Manual

Page 85

Advertising
background image

JKSSS+ Series - 79

JKSSS+ Series

2.3 - 4.2KV

MP.7 Statistics (Metering Page 7)

Displays the statistical trip information.

Screen 1: Displays the total of megawatt hours.

Screen 2: Displays the accumulated total running hours.

Screen 3: Clears the total running hour count.

Screen 4: Displays the total number of trips since the

last clearing the statistical data and the total

number of short circuit trips.

Screen 5: Displays the numbers of start overload and

run overload trips since the last clearing of the

statistical data.

Screen 6: Displays the number of frequency trips and

Imbalance trips.

Screen 7: Displays the number of overcurrent trips.

Screen 8: Displays the number of Stator and non-Stator

RTD Trips.

Screen 9: Displays the number of Ground Fault Hi and

Lo Set trips.

Screen 10: Displays the number of acceleration time trips.

Screen 11: Displays the number of start under curve trips.

Screen 12: Displays the number start over curve trips.

Screen 13: Displays the number of I

2

T start curve trips.

Screen 14: Displays the number of learned start curve

trips.

Screen 15: Displays the number of fail shunt trips.

Screen 16: Displays the number of phase loss trips.

Screen 17: Displays the number of tachometer

acceleration trips.

Screen 18: Displays the number of undervoltage and

overvoltage trips.

Screen 19: Displays the number of power factor trips.

Screen 20: Displays the number of phase reversal trips.

Screen 21: Displays the number of external input #1 trips.

Screen 22: Displays the number of external input #2 trips.

Screen 23: Displays the number of external input #3 trips.

Screen 24: Displays the number of external input #4 trips.

Screen 25: Requires a Security Level 2 password to clear

the statistics.

RUNNING HOURS TOTAL
TIME: ## ## HOURS

TOTAL TRIPS: ###

S/C TRIPS: ###

START O/L TRIPS: ###

RUN O/L TRIPS: ###

I/B TRIPS: ###

OVERCURRENT

TRIPS: ###

STATOR TRIPS: ###

G/F HISET TRIPS: ###
G/F LOSET TRIPS: ###

ACCELERATION TIME

TRIPS: ###

START UNDER CURVE

TRIPS: ###

START OVER CURVE

TRIPS: ###

PRESS ENTER TO

CLEAR RUN HOURS

MENU

METERING PAGE 7
STATISTICS

Screen 5

Screen 6

Screen 7

Screen 8

Screen 9

Screen 10

Screen 11

Screen 12

Screen 13

Screen 14

Screen 15

Screen 16

Screen 17

Screen 18

Screen 22

Screen 23

Screen 24

Screen 25

Screen 4

MWH TOTAL

: ###

Screen 1

Screen 2

Screen 3

NON-STATOR TRIPS: ###

FREQUENCY TRIPS: ###

I*I*T START CURVE
TRIPS: ###

TRIPS: ###

FAIL SHUNT TRIP
TRIPS: ###

PHASE LOSS TRIP
TRIPS: ###

TACH ACCEL TRIP
TRIPS: ###

U/V TRIPS: ###
O/V TRIPS: ###

Screen 19

POWER FACTOR
TRIPS: ###

Screen 20

PHASE REVERSAL
TRIPS: ###

Screen 21

EXT INP #1: ###

EXT INP #2: ###

EXT INP #3: ###

EXT INP #4: ###

PRESS ENTER TO
CLEAR STATISTICS

LEVEL 2 Password required

LEARNED START CURVE

Advertising