2-1. louver control, Dry operation, 3. dry operation – Toshiba RAS-10SAX User Manual

Page 13

Advertising
background image

– 13 –

7-2-1. Louver Control

(1) By pushing the SET button of the remote control

during the operation, the louver can be set to the

desired position.

And the louver position is stored in the microcom-

puter, the louvers will be set to the position au-

tomatically at the next operation.

(2) When the AUTO button is pushed, the louver ver-

tically swings within range of 25deg.

7-3. DRY Operation

(MODE of the remote control : DRY)

(1) Compressor, outdoor fan and operation display

are controlled as shown in Fig. 7-3-1.

Fig. 7-3-2

Fig. 7-3-1

The microprocessor turns the compressor on

and off at regular intervals (4 to 6 minutes on

and/or off). During the compressor off, the

indoor fan will operate in the super low position.

The indoor fan will operate in the AUTO

position.

(2) The pattern of operation depending on the relation

between room temperature and set temperature

is shown below:

Room temp.

Set temp.+1

Set temp.

Compressor

Outdoor fan

Indoor fan

L.

*

S.L.

S.L.

L.

L.

S.L.

L.

ON

ON

ON

ON

OFF

OFF

OFF

*

Super Low

(Room temp. – Set temp.)

Set
temp.

ON

+3

+2

+1

0

OFF

OPERATION

display

Compressor Outdoor fan

(RY01)

Common relay

(RY02)

ON:6min.

OFF:4min.

ON:5min.

OFF:5min.

ON

Advertising
This manual is related to the following products: