– 15 –

7-5. ECONO. Mode

When the ECONO. button is pushed, during COOL

and AUTO operation, the OPERATION display is

turned off and the ECONO. display is lit and the indoor

unit operates quietly and mildly with controlling airflow.

7-5-1. Cooling

(1) In the ECONO. mode, the set temp. by the remote

control is changed automatically as shown in Fig.

7-5-1.

(2) Fan speed

LOW

+2

+1

Set temp.

1H

2H

TIME

0H

(˚C)

ECONO. button
is pushed

Set temp.
is changed

Set temp.
is changed

7-6. Low-Temperature Limit Control

(Cooling Operation)

The microprocessor detects the indoor heat exchanger

temperature so as to prevent freezing up the indoor

heat exchanger.

Control is performed as shown in Fig. 7-6-1.

Fig. 7-5-1

Compressor

Less than 5˚C continues

for 5 minutes

OFF

ON

Outdoor fan

7

Heat exchanger

temperature

5

(˚C)

Fig. 7-6-1