4-3. wiring connection, Warning – Toshiba RAS-10SAX User Manual

Page 24

Advertising
background image

– 24 –

Fig. 8-4-6

How to open the screw cap

• Place your finger on the lower part and push

up to open the screw cap.

(1) Open the screw caps and remove the two screws

securing the front cabinet.

(2) Close the screw caps as behind.

(3) Open the vertical airflow louver horizontally by

hand.

(4) Slightly open the lower part of the front cabinet

then pull the upper part of the front cabinet toward

you to remove it from the rear plate.

Taking out the power cord

• Cut off the slitted portion in the side face of the

rear panel to take out the power cord. After

this, remove burrs, sharp edges, etc., to

smooth the cut face.

<How to connect the power cord>

For the air conditioner that has no power cord,

connect a power cord to it as mentioned below.

• After removing the front cabinet, remove the

terminal cover and the cord clamp.

• Connect and secure the power supply cord and

secure the cord clamp and the terminal cover.

• Cut the rear panel following the cutting mark and

put the power supply cord through the notch.

• Be sure to smooth out the notch with a file, etc.

8-4-3. Wiring Connection

WARNING

To plug the cable in the plug receptacle, take the

following precaution.

THIS APPLIANCE MUST BE EARTHED.

IMPORTANT

THE WIRES IN THIS MAINS LEAD ARE COLORED

IN ACCORDANCE WITH THE FOLLOWING CODE:

Fig. 8-4-5

As the colors of the flexible cord of this appliance may

not correspond with the colored markings, to identify

terminals in your plug, as follows:

Connect BROWN colored core to plug terminal marked

letter "L".

Connect BLUE colored core to plug terminal marked

letter "N".

Connect GREEN AND YELLOW colored core to plug

terminal marked Earth Symbol "

".

<How to remove the front cabinet>

Slitted portion

NOTE :

• Use standard wire only.

• Wire type: More than H05-RN-F

Fig. 8-4-8

Fig. 8-4-7

<Stripping length of power cord>

3

2

2

1

1

4

4

Vertical air flow louver.

L

N

L

N

-LIVE

-NEUTRAL

-EARTH

: Brown

: Blue

: Green and Yellow

Earth line

40mm

10mm

10mm

30mm

L

N

Cord clamp

Terminal cover

Screw

Power supply
cord

Terminal block

Earth line

Screw

Screw

L

N

Advertising