Toshiba RAS-10SAX User Manual

Page 39

Advertising
background image

– 39 –

9-3-2. Power can not be Turned on after Replacing Indoor PC Board

<Checking Procedure>

9-3-3. Outdoor Unit does not Operate

RY01

C02

RY02

Brown

N

L

Power
terminal
block

T02

PC board

Blue

White

Black

1

2

Indoor
terminal
block

To the paragraph of
“No Power turns on”.

Does the OPERATION

lamp flash?

YES

NO

Connect the AC

Power supply

Return the wiring of the
power relay is returned to
the normal procedure.

Is it wired as shown

in Figure below?

YES

NO

Shut off the power supply
from AC outlet once and
turn it on after 5 seconds.

Does the OPERATION lamp flash?

Does the power turn on by

pushing the [START/STOP] button

of the remote control?

Is cable connection

between indoor and outdoor

units correct?

Check items as following procedure
in 9-3-4, 9-3-5, 9-3-6.

Replace the
PC board.

See "Power can not be turned on".

Relays (RY01, RY02)
or IC31 or IC30 is failure.

Correct cabling between
indoor and outdoor units.

NO

NO

NO

NO

YES

YES

YES

YES

See "Power can not be turned on".

Is AC220/230/240V

supplied between terminal block

1 - 2 ?

Advertising
This manual is related to the following products: