Caution – Toshiba RAS-10SAX User Manual

Page 25

Advertising
background image

– 25 –

<How to connect the connecting cable>

Wiring of the connecting cable can be carried out

without removing of the front panel.

(1) Remove the front panel.

Fully open the front panel. Disengage the support

arm located in the upper center while pushing its

handle leftwards, and then remove the front panel

toward you.

(2) Remove the terminal cover and cord clamp.

(3) Insert the connecting cable (according to local

codes) into pipe hole on the wall.

(4) Take out the connecting cable through the cable

slot on the rear panel so that it is exploded by

about 15 cm long in the front side.

(5) Insert the connecting cable fully into the terminal

block and secure it by screw tightly.

(6) Tightening torque:1.2 N•m (0.12 kgf•m)

(7) Secure the connecting cable with the cord clamp.

(8) Fix the terminal cover and front panel on the indoor

unit.

CAUTION

• Be sure to refer the wiring system diagram

labeled inside the front panel.

• Check local electrical codes and also any

specific wiring instructions or limitation.

<Stripping length of connecting cable>

For a three conductor cable

NOTE :

• Use stranded wire only.

• Wire type:More than H05 RN-F

Fig. 8-4-10

<How to install the front cabinet on the indoor

unit>

Install the front cabinet through the opposite order of

"How to remove the front cabinet".

When the panel is removed and mounted again, take

the following actions:

After fastening the two screws, one each at the left

and right of the air outlet, be sure to push the upper

center

1

right end

2

, left end

3

and the lower

center

4

of the air outlet, and confirm that no gap is

left between the front cabinet and the rear plate.

• If cooling (dry) operation is made without

pushing the air outlet, dew can be deposited

on the front cabinet surface. In addition a gap

between the front cabinet and the rear plate

will become wider, spoiling the appearance.

3

1

2

4

Push

Push

Push

Push

Fig. 8-4-11

Fig. 8-4-9

10mm

40mm

50mm

10mm

Earth line

1

2

Connecting
cable

about 15cm

Terminal block

Cord
clamp

Screw

Screw

Connecting cable

Earth
line

Terminal
cover

Screw

2

1

Advertising
This manual is related to the following products: