(2) Self-diagnosis with remote control

With the indoor unit control, self-diagnosis of pro-

tective circuit action can be done by turning the

remote control operation into service mode, oper-

ating the remote control, observing the remote

control indicators and checking whether TIMER

lamp flashes (5 Hz).

Note :

• To perform this self-diagnosis, the remote

control with the service code of 43069666 is

required.

<How to select remote control operation mode>

1) Selecting service mode

Push the switch button provided on rear bot-

tom of the wireless remote control with a tip of

pencil for more than 3 seconds. Make sure

the setting temperature is displayed on

the display and other display is turned off.

2) Selecting ordinary mode

Push the all clear button (ACL) on the rear bot-

tom of the wireless remote control with a tip of

pencil for more than 3 seconds. Make sure

the operation mode display, wind volume dis-

play, clock display and setting temperature dis-

play are turned on and “

: ” of the clock display

is flashing.

<Cautions when doing service>

1) After completion of servicing, always push the

all clear (ACL) button to return the operation

mode to the normal mode.

2) After completion of servicing by the check

code, turn off the power once and then turn on

the power to reset memorized contents of the

microcomputer to the initial status.

Fig. 9-2-1

“ ”

ACL CLOCK

(Rear bottom of remote control)

ACL

CLOCK

All clear button

Switch for selecting
service mode

Rear bottom cover