8-4-5. Indoor Unit Installation

(1) Pass the pipe through the hole in the wall, and

hook the indoor unit on the installation plate at the

upper hooks.

(2) Swing the indoor unit to right and left to confirm

that it is firmly hooked up on the installation plate.

(3) While pressing the indoor unit onto the wall by the

lower part, hook it up on the installation plate by

the lower part. Pull the indoor unit toward you by

the lower part to confirm that it is firmly hooked up

on the installation plate.

8-4-6. Drainage

(1) Run the drain hose sloping downwards.

NOTE :

• Hole should be made at a slight downward slant to

the outdoor side.

Fig. 8-4-19

Fig. 8-4-15

• For detaching the indoor unit from the installation

plate pull the indoor unit toward you while pushing

its bottom up by the specified parts.

Space for pipes

Wall

Drain guide

Fig. 8-4-18

CAUTION

Arrange the drain pipe for proper drainage from

the unit.

Improper drainage can result in damage to

property.

This air conditioner has the structure designed to drain

water collected from dew, which forms on the back of

the indoor unit, to the drain pan.

Therefore, do not store the power cord and other parts

at a height above the drain guide.

Fig. 8-4-17

(2) Put water in the drain pan and make sure that the

water is drained outdoors.

(3) When connecting extension drain hose, insulate

the connecting part of extension drain hose with

5

shield pipe.

Fig. 8-4-16

5 Shield pipe

Extension drain hose

Inside the room

Drain hose

50 mm
or more

Do not rise the drain hose.

Do not form the drain hose
into the wared shape.

Do not put the
drain hose end
into water.

Do not put the drain
hose end in the
drainage ditch.

Push

1 Installation

plate

Hook here

(1)

(2)

Hook

Push

Push