8-4-4. Piping and Drain Hose Installation

<In case of rightward piping>

• After scribing slits of the front panel and the rear

panel by a knife or a marking-off pin, cut them by a

pair of nippers or the like.

To connect pipe after installation of unit (figure)

Fig. 8-4-13

<Left-hand connection with piping>

Bend the connecting pipe so that it is laid within 43

mm above the wall surface. If the connecting pipe is

laid exceeding 43 mm above the wall surface, the

indoor unit may unstably be set on the wall. When

bending the connecting pipe, make sure to use spring

bender so as not to crush the pipe.

Bend the connection pipe within a radius of 30

mm.

Slit (rear panel)

Slit (front panel)

Fig. 8-4-14

NOTE :

If the pipe is bent incorrectly, the indoor unit may

unstably be set on the wall.

After passing the connecting pipe through the pipe

hole, connect the connecting pipe to auxiliary pipes

and wrap the facing tape around them.

CAUTION

• Bind the auxiliary pipes (two) and connecting

cable with facing tape tightly. In case of leftward

piping and rear-leftward piping, bind the

auxiliary pipes (two) only with facing tape.

• Carefully arrange pipes so that any pipe does

not stick out of the rear plate of the indoor unit.

• Carefully connect the auxiliary pipes and

connecting pipes to each other and cut off the

insulating tape wound on the connecting pipe

to avoid double-taping at the joint, moreover,

seal the joint with the vinyl tape, etc.

• Since dewing results in a machine trouble,

make sure to insulate both the connecting

pipes. (Use polyethylene foam as insulating

material.)

• When bending a pipe, carefully do it not to

crush it.

196mm

96mm

Side of liquid flow

Side of gas flow

Outward form of indoor unit

(To the forefront of flare)

R 30mm (Use polisin or the like for bending pipe.)

43mm

Use the handle of screwdriver,etc.

80˚

Fig. 8-4-12

<In case of downward piping>

• After scribing the slit of the front panel and slit in

the lower part of the rear panel by a knife or a

marking-off pin, cut them by a pair of nippers or

the like.

Slit (rear panel)

Slit (front panel)

Indoor unit

Connecting
cable

Installation
plate

Auxiliary
pipes