– 47 –

Table 9-4-2 Approximate value of the sensor (thermistor) resistance (TA, TC)

(= k

)

9-4-3. How to Reduce the Operation Time of

the Anti-Restart Timer

• Attach the diode (1S1555 or equivalent) to the rivet

inside the unit through holes on the rear of the

wireless remote control unit.

• Push the START/STOP button to start operation

with the diode attached.

Fig. 9-4-1

Temperature

Sensor

Themo Sensor

0°C

35.8

10°C

20.7

20°C

12.6

25°C

10.0

30°C

7.92

Timer short diode