3-6. only the indoor fan does not operate – Toshiba RAS-10SAX User Manual

Page 42

Advertising
background image

– 42 –

9-3-6. Only the Indoor Fan does not Operate

< Check procedure >

YES

NO

Replace the
PC board.

Shut off the power
supply once.

Does the fan

stop in no operating

status?

Control PC board is defective.

Replace the PC board.

Start the operation
with low fan setting
in cool operation.

Does the fan rotate?

Change the setting of
cooling to high fan.

Does the fan speed

become higher?

Operation
stops

Normal

Is the voltage

measured DC35V

between

1

(red lead wire, +)

and

2

(black lead wire, –)

of the motor connector

(CN10) ?

Shut off the power supply.

Does the cross

flow fan rotate

normally?

Repair the
bearing of
the drain fan.

Turn on the power supply.

Is the rotation signal

(DC+5V-0V) output between

4

(blue lead wire) and

2

(black

lead wire) of the motor connector

(CN10) when rotating the cross

flow fan by hand in no operating

status ? (2 pulses/one turn)

Replace the control
PC board.

Shut off the power supply,
and turn it on after
disconnecting the motor
connector (CN10)

*

from

the PC board.

Is the voltage of

DC35V measured

between 1 (red lead wire, +)

and 2 (black lead wire, –) of

the motor connector

(CN10) ?

Replace the
fan motor.

YES

NO

YES

NO

YES

NO

YES

NO

YES

NO

YES

NO

Turn the power supply.

*

Be sure to disconnect the motor connector CN10 after shut off the power supply, or it will be a cause of

damage of the motor.

Advertising