Auto restart function, 7-1. how to set the auto restart, 7. auto restart function – Toshiba RAS-10SAX User Manual

Page 16

Advertising
background image

– 16 –

7-7. Auto Restart Function

This unit is equipped with an Automatic restarting

facility which allows the unit to restart and resume the

set operating conditions in the event of a power supply

shutdown without the use of the hand control.

The operation will resume without warning three

minutes after the power is restored.

The Auto Restar t function is set not to work on

shipment from the factory, and so it is necessary to

set it to function as required.

7-7-1. How to Set the Auto Restart

To set the Auto Restart function, proceed as follows:

Access the TEMPORARY button located in the lower

right hand corner beneath the hinged front panel of

the indoor unit (please refer to section on PARTS

NAME). The power supply to the unit must be on -

the function will not be set if the power is off.

To enable the Auto Restar t function, press the

TEMPORARY button continuously for three seconds.

The unit will acknowledge the setting and beep three

times. The system will now restart automatically.

The above Auto Restart settings can be carried out:

During subsequent operation, the orange light is lit.

• The Auto Restart function will not accept an

instruction if timer operation with the remote control

is selected.

(Please refer to the section on setting the timer or

setting the louver.)

• When the system is stand-by (not running)

• During louver swing (AUTO) operation, after restart

by the Auto Restart function the louver swing stops.

• When the system is operating

OPERATION

Press the TEMPORARY button
continuously more than three
seconds.

MOTION

Stand-by

The system starts to operate.

The green light will be lit.

about three seconds after

The unit beeps three times.

The orange light will be lit.

The system is operating.

The orange light is lighting.

If the system is not required to run at this time, press the TEMPORARY
button once more or use the remote control and the unit will stop.

OPERATION

Press the TEMPORARY button
continuously more than three
seconds.

MOTION

Operating

The green light is lit.

The system stops to operate.

The green light is turned off.

about three seconds after

The unit beeps three times.

The system stops.

If the system is not required to stop at this time, use the remote control
and to restart.

TEMPORARY

0

3S

TEMPORARY

0

3S

Advertising
This manual is related to the following products: