Cooling fan filters, Maintenance schedule – Universal Laser Systems X2-600 User Manual

Page 110

Advertising
background image

7-8

Maintenance



Cooling Fan Filters


This air-cooled laser system will require periodic
cleaning of the cooling fan filters. Since
ambient air is used to cool the laser tube, the air
must be filtered before it enters the inside of the
laser system otherwise dirt and dust can build
up inside of the laser system and damage it.
The contaminants reduce the laser system’s
cooling ability and will cause the laser tube to
overheat. An overheated tube will lose laser
power during engraving and will eventually shut
down completely. The laser tube has a built in
safety mechanism that will shut the beam off
before it can damage itself.

The cooling fan filters are located on the back of the laser system. Do not push the laser system all the
way back against the wall because air needs to circulate behind the laser system. Since there is a variety
of laser power options available for this class of laser system

, the cooling fan filters may differ in

appearance compared to your system. Regardless, you should remove and clean these filters at least
once a week depending on your environmental conditions. Dirtier environments require more frequent
cleanings. To remove the filter(s), simply snap off the black cover and remove the foam element. Wash
the element in a soap and water solution, dry, and re-install.


Maintenance Schedule


Since the maintenance requirements of the laser system is dependent on the type of material being run,
the quantity of material being removed, the hours of operation, and the quality of the exhaust blower, it
must be user defined. As a starting point, we recommend checking and, if necessary, cleaning the laser
system after

EVERY 8 HOURS of engraving or cutting. Depending on your particular operation, you may

need to adjust this schedule. If you are noticing a considerable buildup of debris on the optics and the
motion system, clean the system at more frequent intervals. If your system has remained relatively clean,
you can extend your cleaning intervals. You need to be the judge but keep in mind that a clean machine
is a better performing machine and can extend the life of the parts as well as reduce the possibility of
down time. Maintaining and cleaning the laser system should not take more than five (5) minutes a day.
If you have any questions about maintaining the laser system, please contact our Service Department.











NEVER OPERATE THE LASER SYSTEM WITH THE COOLING FAN FILTERS
REMOVED.
This can permanently damage the laser system. Damage from this kind
of abuse WILL NOT be covered under warranty.