Universal Laser Systems X2-600 User Manual

Page 112

Advertising
background image

8-2

Troubleshooting


Raster engraving appears sharp on
both ends of the engraving but fuzzy
in the middle

•

Dirty laser system

•

Something is loose

•

System needs tuning

•

Worn X-axis belt and/or drive gear


•

Tickle setting too low

•

Faulty laser tube

•

Clean all optics, rails, bearings and belts

•

Check X-axis bearings, drive gear, idler
pulley, belt, and optics

•

Run “Tuning” feature in printer driver version
4.17 and higher

•

Replace belt and/or drive gear, and run
“Tuning” feature

•

Adjust setting higher and recheck

•

Replace laser tube

Engraving does not appear as deep
as it normally does

•

Graphic, graphic software, graphic software
setup, color palette, monitor display colors, or
driver settings have changed

•

Out of focus

•

Material or material density has changed

•

Settings have changed

•

Dirty laser system

•

Laser tube cooling fan filters are dirty

•

Chiller not maintaining temperature(water
cooled versions only)

•

Ambient temperature not within specifications

•

Laser beam out of alignment with the optics

•

Air Assist cone misaligned (air assisted
versions only)

•

Faulty laser tube

•

Check to see what has changed. Use
“Software Setup Guide” to properly setup the
graphics software to work correctly with the
laser system. Check driver settings.

•

Re-focus

•

Check material

•

Check power, speed, PPI, and DPI settings

•

Clean all optics, rails, bearings and belts

•

Check and/or clean

•

Check, clean, or adjust chiller

•

Adjust ambient temperature to within
specifications

•

Check and/or adjust laser beam alignment

•

Check and/or adjust cone so that laser beam
is in center

•

Replace laser tube

Engraving is sharp, clear and at a
good depth on one side of the table
and fuzzy and shallow on the
opposite side of the table

•

Out of focus

•

Dirty laser system

•

Material is not level or varying in thickness


•

Table is not level




•

Laser beam out of alignment with the optics

•

Air Assist cone misaligned (air assisted
versions only)

•

Faulty laser tube

•

Re-focus

•

Clean all optics, rails, bearings and belts

•

Check focus point of material and different
places, adjust height by shimming material or
using more thickness-consistent material

•

Using the focus tool, focus directly on the
surface of the table in all four corners. Table
should be within +/- .020 inches from one
corner to the other. Adjust if necessary.

•

Check and/or adjust laser beam alignment

•

Check and/or adjust cone so that laser beam
is in center

•

Replace laser tube