3-25




To Adjust AUTOFOCUS:
From time to time, you may need to re-adjust your AUTOFOCUS. The only time that you should need to
re-adjust the AUTOFOCUS is when you have received a new or different length Focus Lens, have
recently Flash upgraded the operating system of the laser, or had a dirty sensor or reflector and are
adjusting it after you have cleaned those parts.

Place a very flat object on the Engraving Table, within the AUTOFOCUS Zone, that is at least 1 inch
thick.

AUTOFOCUS on this object by pressing the “Z” button once.

While you are still in the “Z Position” display, move the Focus Carriage using the motion control keys
so that it is above your object that you placed on the table.

Place your Focus Tool on top of your object and compare the Focus Tool reading with the actual
height that the AUTOFOCUS set the Engraving Table to. If it is not the same, bring the cursor up to
the first line of the “Z Position” display and press the “Select” button. Now focus on your object by
using your Focus Tool and adjusting the “Z Position” until your are manually focused on top of your
object.

Press the “Escape” button, move the cursor to the “Set Focal Length” line and press “Select”. It will
ask you if you are sure so move the cursor down to the “YES” line and press “Select”. The
AUTOFOCUS will now have been re-adjusted to be exactly at the same height as your Focus Tool.
The purpose of “Setting the Focus Length” is to calibrate AUTOFOCUS with your Focus Tool so that
whether you use AUTOFOCUS or use the Focus Tool, you will always be putting the Engraving Table
at the correct focusing height.

If you have purchased additional lenses, repeat this procedure for each lens by changing the
“CURRENT LENS” on the display and your focus tool, to the one you are calibrating.



AUTOFOCUS Maintenance:
If the AUTOFOCUS reflector or sensor becomes dirty from engraving smoke, it may malfunction. A sign
of AUTOFOCUS malfunction is upon activation, the table either moves all the way down to the bottom or
all the way up to the top and will try to keep on moving until you power the machine off. If this did
happen, you will need to clean your sensor and reflector and then perform the AUTOFOCUS adjustment
procedure. An indication that the sensor and reflector are clean is that you will see a little green light
appear on the side of the sensor. If you see both green and red lights, the sensor and/or reflector are
dirty or blocked.

NOTE: Make sure that the table is down far enough so that the sensor “sees” the

reflector before assuming that there is a problem.

To clean, dampen a tissue with water and gently wipe across the sensor and reflector in one direction.
Gently wipe again with a dry tissue.