Universal Laser Systems X2-600 User Manual

Page 41

Advertising
background image

3-16 System Operation



To restore the focus position back to the original factory setting, go back into this menu and press the up
and down arrow keys simultaneously.


You will see the motion system move to the 1 inch horizontal and the 1 inch vertical position (factory
default). Now select “YES, SAVE POSITION”. Press the “ESCAPE” button twice to exit back to the
“MAIN” menu. Your settings will automatically be retained permanently in memory.


SET ROTARY AXIS Menu
The Rotary Fixture Axis is a setting that is pre-set at the factory. The laser system will sense when the
Rotary Fixture is plugged in and will position the X-Axis arm directly over the centerline of rotation
automatically when it begins to engrave. This setting can be altered if you position the Rotary Fixture in a
location

OTHER than the factory set position. Please refer to the section on the optional Rotary Fixture

for a full description on how to set up and use this device before altering any factory setting.

To change the factory default setting, turn the laser system OFF, place the Rotary Fixture on the
engraving table in the desired position, and

DO NOT plug the Rotary Fixture into the electrical socket.

Now turn the laser system on and with the motion system arrow buttons, position the X-Axis arm’s focus
lens carriage directly over the Rotary Fixtures centerline of rotation as the following diagram illustrates:


The left and right position (X-position) of the focus carriage is irrelevant in this setting and is not shown in
the display. Now select the “YES SAVE Y AXIS” choice. If you change your mind and do not wish to
alter the “ROTARY AXIS” position, select “CANCEL” instead and the original settings will be restored.
Remember, always escape back to the “MAIN” menu before turning the system off so that your settings
will be permanently stored in memory.