Installation

2-7


Leveling the System


1. If the floor underneath the

Laser System is uneven, the
casters must be adjusted.
Place a bubble level across the
top of the legs directly above
the front casters. Note the
bubble position in its sight
glass. Do the same for the
back part of the legs and also
note the position of the bubble
in the sight glass. If the bubbles
are in the same visual position,
adjustment is not necessary
and cart assembly is complete.
If they are in different positions,
adjustment is required.

2. To adjust the casters, choose

ONLY ONE (1) caster and
adjust its height until both
bubbles are visually identical
between the front casters and
the back casters. The purpose
of this step is to make sure that
all casters lie in the same
plane, not to level the laser
system with the ground. If
desired, you can level the laser
system

with

the

ground

although it is not required.

3. Open the top door and remove the rubber band that is holding the arm in place.
4. If you haven’t already done so, remove any remaining packing materials, accessories or any other

items that may be located inside the cabinet or on top of the engraving table.

5. Gain access to the rear of the laser system to install the Laser Cartridge.

Laser Cartridge Installation


Before connecting and powering on your system, you must install the Laser Cartridge(s). Make sure that
your power cord

IS NOT plugged in at this time.


The following procedure is for both the X-600 and the X2-600 Platforms. The difference is that the X2-
600 can accommodate one or two Laser Cartridges.

No matter which system you have, if you only

have one Laser Cartridge, install it in the TOP position.