2-8

Installation



Open the Rear Cover and visually locate the Laser Mounting Block(s), the Laser Latch(es), and
Alignment Fork(s). Notice that the Alignment Fork(s) have two plates, one small and one large. Locate
the gap between the two plates.

Observe the “V” groove along the upper and lower part of the Laser Cartridge. Also locate the Alignment
Plate at the end of the Laser Cartridge.


Pick up the Laser Cartridge by the sides. Tilt the Laser Cartridge downward on a 30-degree angle. If you
have the X2-600 and you have two(2) Laser Cartridges, mount the cartridge onto the

LOWER Mounting

Blocks first. It does not matter if the power rating is different between the two lasers. Place the upper “V”
groove of the cartridge on top of the Mounting Blocks. Slide the cartridge to the right until the Alignment
Plate of the Laser Cartridge makes contact with the inside of the large plate of the Alignment Fork and is
centered in the gap in the Alignment Fork between the small and large plates of the Alignment Fork.

Slowly rotate the Laser Cartridge making sure that the Alignment Plate is centered in the gap of the
Alignment Fork. Keep rotating the laser until the Laser Latch “clicks” and locks the cartridge into place.
Make sure that you do not pinch any wires or hoses during this process. This may require some
slight force to actuate the latch. Verify that the cartridge is resting,

UNTILTED, and the Alignment Plate is

centered within the Alignment Fork. If you have a second Laser Cartridge, mount it on the top mounts the
same as the bottom Laser Cartridge. Remember if you only have one laser, mount it on the

TOP Laser

Mounts.