Maintenance and service – Bosch BL 200 GC Professional User Manual

Page 35

Advertising
background image

English | 35

Bosch Power Tools

1 609 929 L80 | (26.7.07)

Overview of Indications

Maintenance and Service

Maintenance and Cleaning

Keep the measuring tool clean at all times.
Wipe away debris or contamination with a dry,
soft cloth. Do not use cleaning agents or solvents.
Regularly clean the surfaces at the exit opening
of the laser in particular, and pay attention to
any fluff of fibres.
When heavily contaminated, the measuring tool
can be cleaned under running water. Do not im-
merse the measuring tool in water and do not
subject it to a high-pressure water jet.

If the measuring tool should fail despite the care
taken in manufacturing and testing procedures,
repair should be carried out by an authorized af-
ter-sales service centre for Bosch power tools.
In all correspondence and spare parts orders,
please always include the 10-digit article
number given on the type plate of the measuring
tool.

Spare Parts

Rubber foot 14 (3 pce.) . . . . . . . 1 609 203 588
Battery lid 13 . . . . . . . . . . . . . . 1 609 203 M02
Battery pack 15 . . . . . . . . . . . . 1 609 203 M04

Laser beam

Rotation

of the laser*

Warning

signal

Switching on the measuring tool (3 s self-check) z

z

z

z

z

Measuring tool levelled in/ready for operation z

z

z

Levelling in or re-levelling

2x/1 s 

2x/1 s

Self-levelling range exceeded

1x/1 s 

1x/1 s 1x/1 s 1x/1 s

Out-of-level shutoff activated

1x/4 s

Out-of-level shutoff actuated





4x/1 s

2x/1 s

Automatic levelling switched off

1x/1 s

Inclined operation in a single axis is switched on

1x/1 s 1x/1 s

Stand-by-operation with Storage of the
Operating Mode





1x/5 s

Battery voltage low

1x/2 s

Battery empty

z

Malfunction









z

* for line and rotational operation
1x/1 s

z



Flashing frequency (e.g. once per second)
Continuous operation
Function stopped

OBJ_BUCH-78-004.book Page 35 Thursday, July 26, 2007 2:04 PM

Advertising